SCHNEIDER PowerLogic PM8000 - PM8240 Panel mount meter - intermediate metering

SCHNEIDER PowerLogic PM8000 - PM8240 Panel mount meter - intermediate metering

0 筆商品評論 0 sold. Only 10 remain
$15,000.00
型號: YTPM8240
庫存狀態: 有現貨
Viewed 1449 times

Product Description

Main
rangePowerLogic
product namePowerLogic PM8000
device short namePM8240
product or component typePower meter

Complementary
power quality analysisConforming to EN 50160: 2010 compliance report
conforming to IEEE 519: 2014 compliance report
conforming to IEC 61000-4-30: class S power quality measurement
up to the 63rd harmonic
harmonic distortion
waveform capture
voltage sag and swell detection
programmablity (logic and math functions)
conforming to IEC 62586 power quality monitoring
device applicationPower monitoring
WAGES metering
type of measurementCurrent
Voltage
Frequency
Active and reactive power total
Apparent power total
Power factor total
Active and reactive power per phase, rms
Apparent power per phase, rms
Power factor per phase, rms
supply voltage90...415 V AC 45...65 Hz +/- 10 %
110...415 V DC +/- 10 %
network frequency50 Hz
60 Hz
[In] rated current1 A
5 A
10 A
poles description3P + N
3P
1P + N
power consumption in VA18 VA at 415 V AC
display typeColour TFT LCD
display resolution320 x 240 pixels QVGA
sampling rate256 samples/cycle
measurement current50…10000 mA
analogue input typeVoltage (impedance 5 MOhm)
Current (impedance 0.3 mOhm)
measurement voltage57…400 V AC 42...69 Hz between phase and neutral
100…690 V AC 42...69 Hz between phases
frequency measurement range42…69 Hz
number of inputs3 digital 30 V AC
3 digital 60 V DC
measurement accuracyCurrent +/- 0.1 %
Voltage +/- 0.1 %
Active energy +/- 0.2 %
accuracy classClass 0.2S active energy conforming to IEC 62053-22
Class 0.2 active energy conforming to ANSI C12.20
Class 0.2 active power conforming to IEC 61557-12
Class 0.5S reactive energy conforming to IEC 62053-24
Class 0.5 power factor conforming to IEC 61557-12
Class 0.2 voltage conforming to IEC 61557-12
Class 0.2 current conforming to IEC 61557-12
number of outputs1 pulse
information displayedVoltage
Current
Frequency
Power
Energy consumption
Harmonic distortion
communication port protocolModbus RTU at 115 kbauds - 2-wire
ION at 115 kbauds - 2-wire
DNP3
IEC 61850
Modbus TCP/IP
Ethernet Modbus TCP/IP daisy chain at 10/100 Mbit/s
RSTP 801.1d 2004
communication port supportEthernet
Screw terminal block: RS485
communication network typeIPv6 (internet protocol)
data recordingMin/max of instantaneous values
Waveform logs
Sequence of event recording
Time stamping
Alarm logs
Trending/forecasting
Sag and swell logs
Harmonics logs
GPS synchronisation
Data logs
Event logs
memory capacity512 MB
web servicesCustomizable home page
File upload/download via FTP
File upload/download via SFTP
Web server
Alarm notification by e-mail
Viewing of captured waveform (FTP)
Viewing of captured waveform (web)
HTTPS server
communication serviceSMTP e-mail notification
RSTP support
NTP time synchronization
DHCP
PTP time synchronization
cybersecurityEnable/disable communication ports
Password protection
Syslog protocol support
Robust security logs
Port hardening
mounting modeFlush-mounted
mounting supportFramework
installation categoryIII
Safety ConstructionIII400…690 V conforming to IEC 61010-1:ed. 3
III400…690 V conforming to EN 61010-1:ed. 3
III347…600 V conforming to UL 61010-1:ed. 3
III347…600 V conforming to CSA C22.2 No 61010-1:ed. 3
standardsIEC 61557-12
IEC 62052-11
IEC 62053-24
IEC 62053-22
IEEE 1588
IEC 62586-2
IEC 61326-1
product certificationsCE
CULus
N998
width96 mm
depth77.5 mm
height96 mm
net weight581 g

Environment
electromagnetic compatibilityElectrostatic discharge conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test conforming to IEC 61000-4-4
Surge immunity test conforming to IEC 61000-4-5
Conducted RF disturbances conforming to IEC 61000-4-6
Magnetic field at power frequency conforming to IEC 61000-4-8
Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
Immunity to impulse waves conforming to IEC 61000-4-12
Conducted and radiated emissions conforming to EN 55022
Conducted and radiated emissions conforming to EN 55011
Conducted and radiated emissions conforming to FCC part 15
Conducted and radiated emissions conforming to ICES-003
Conducted RF disturbances (2...150 Hz) conforming to CLC/TR 50579
Surge withstand conforming to IEEE C37.90.1
IP degree of protectionIP54 front: conforming to IEC 60529
IP30 body: conforming to IEC 60529
relative humidity5…95 %
ambient air temperature for operation-25…70 °C
ambient air temperature for storage-40…85 °C
operating altitude3000 m

Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Weight0.954 kg
Package 1 Height14 cm
Package 1 width14 cm
Package 1 Length18.5 cm

如果您對本商品有什麼問題或經驗,請在此留下您的意見和建議!

注意: 評論內容不支援HTML代碼!
    差評           好評

When you order from opencartworks.com, you will receive a confirmation email. Once your order is shipped, you will be emailed the tracking information for your order's shipment. You can choose your preferred shipping method on the Order Information page during the checkout process.

The total time it takes to receive your order is shown below:

img

The total delivery time is calculated from the time your order is placed until the time it is delivered to you. Total delivery time is broken down into processing time and shipping time.

Processing time: The time it takes to prepare your item(s) to ship from our warehouse. This includes preparing your items, performing quality checks, and packing for shipment.

Shipping time: The time for your item(s) to tarvel from our warehouse to your destination.

Shipping from your local warehouse is significantly faster. Some charges may apply.

In addition, the transit time depends on where you're located and where your package comes from. If you want to know more information, please contact the customer service. We will settle your problem as soon as possible. Enjoy shopping!

Size Chart